Search Results

You searched for the following terms: "clean%". Oasys removes some common words (such as is, at, and etc), and restricts to a maximum of 5 words, so this list may not be the same as the one you entered.

Showing Page 8 of 9 Page: 3 4 5 6 7 8 9
Download these 176 result(s) in MedlineFormat

Abstract Available for Airway obstruction in boilermakers exposed to fuel oil ash. A prospective investigation Hauser R, Elreedy S, Hoppin JA, Christiani DC, Airway obstruction in boilermakers exposed to fuel oil ash. A prospective investigation, Am J Respir Crit Care Med, 1995;152:Pt 1):1478-84,

Abstract Available for Work-related respiratory problems in industrial arts teachers Ahman M, Soderman E, Cynkier I, KolmodinHedman B, Work-related respiratory problems in industrial arts teachers, Int Arch Occup Environ Health, 1995;67:111-118,

Abstract Available for Hypersensitivity pneumonitis induced by dust from an automatic bed cleaner Fujiuchi S, Nishigaki Y, Yamaguchi S, Akiba Y, Osanai S, Yamazaki Y, Nakano H, Ohsaki Y, Kikuchi K, Hypersensitivity pneumonitis induced by dust from an automatic bed cleaner, Nippon Kyobu Shikkan Gakkai Zasshi, 1995;33:564-568,

No Abstract Available for Occupational asthma due to chloramine-T solution Kujala VM, Reijula KE, Ruotsalainen E, Heikkinen K, Occupational asthma due to chloramine-T solution, Respir Med, 1995;89:693-695,

Abstract Available for Exposure to dust and rat urinary aeroallergens in research establishments Nieuwenhuijsen MJ, Gordon S, Tee RD, Venables KM, McDonald JC, Newman Taylor AJ, Exposure to dust and rat urinary aeroallergens in research establishments, Occup Environ Med, 1994;51:593-596,
Tony Newman Taylor, Royal Brompton Hospital, London, an author of 'Exposure to dust and rat urinary aeroallergens in research establishments' Kate Venables, Oxford University, an author of 'Exposure to dust and rat urinary aeroallergens in research establishments' Rosemary Tee, Royal Brompton Hospital, an author of 'Exposure to dust and rat urinary aeroallergens in research establishments'

Abstract Available for Risks of asthma associated with occupations in a community-based case-control study Ng TP, Hong CY, Goh LG, Wong ML, Koh KT, Ling SL, Risks of asthma associated with occupations in a community-based case-control study, Am J Industr Med, 1994;25:709-718,

Abstract Available for Do latex allergens potentiate other skin tests? Moneo I, Alday E, Do latex allergens potentiate other skin tests?, Allergol Immunopathol, 1994;22:39-41,

Abstract Available for A combined respiratory and cutaneous hypersensitivity syndrome induced by work exposure to quaternary amines Bernstein JA, Stauder T, Bernstein DI, Bernstein IL, A combined respiratory and cutaneous hypersensitivity syndrome induced by work exposure to quaternary amines, J Allergy Clin Immunol, 1994;94:257-9,
David Bernstein, Cincinatti, an author of 'A combined respiratory and cutaneous hypersensitivity syndrome induced by work exposure to quaternary amines' Leonard Bernstein, Cincinatti, an author of 'A combined respiratory and cutaneous hypersensitivity syndrome induced by work exposure to quaternary amines'

Full Text Available for Occupational asthma due to indirect exposure to lauryl dimethyl benzyl ammonium chloride used in a floor cleaner Burge PS, Richardson MN, Occupational asthma due to indirect exposure to lauryl dimethyl benzyl ammonium chloride used in a floor cleaner, Thorax, 1994;49:842-843,
Sherwood Burge, Oasys, an author of 'Occupational asthma due to indirect exposure to lauryl dimethyl benzyl ammonium chloride used in a floor cleaner'

Abstract Available for Occupational asthma caused by ethanolamines. Savonius B, Keskinen H, Tuppurainen M, Kanerva L, Occupational asthma caused by ethanolamines., Allergy, 1994;49:877-81,

Abstract Available for Hypersensitivity Pneumonitis and Exposure to Acid-Fast Bacilli in Coolant Aerosols Muilenberg ML, Burge HA, Sweet T, Hypersensitivity Pneumonitis and Exposure to Acid-Fast Bacilli in Coolant Aerosols, J Allergy Clin Immunol, 1993;91:311-,
Harriet Burge, , an author of 'Hypersensitivity Pneumonitis and Exposure to Acid-Fast Bacilli in Coolant Aerosols'

Abstract Available for Occupational asthma in a technologist exposed to glutaraldehyde ChanYeung M, McMurren T, CatonioBegley F, Lam S, Occupational asthma in a technologist exposed to glutaraldehyde, J Allergy Clin Immunol, 1993;91:974-978,
Moira Chan-Yeung, University of Hong Kong, an author of 'Occupational asthma in a technologist exposed to glutaraldehyde'

Abstract Available for Respiratory function in sewage workers Zuskin E, Mustajbegovic J, Schachter EN, Respiratory function in sewage workers, Am J Industr Med, 1993;23:751-761,

Abstract Available for Chlorine gas exposure and the lung: a review Das R, Blanc PD, Chlorine gas exposure and the lung: a review, Toxicology & Industrial Health, 1993;9:439-455,
Paul Blanc, University of California San Francisco, an author of 'Chlorine gas exposure and the lung: a review'

Abstract Available for Reduction of airborne allergenic urinary proteins from laboratory rats Gordon S, Tee RD, Lowson D, Wallace J, Newman Taylor AJ, Reduction of airborne allergenic urinary proteins from laboratory rats, Brit J Industr Med, 1992;49:416-422,
Tony Newman Taylor, Royal Brompton Hospital, London, an author of 'Reduction of airborne allergenic urinary proteins from laboratory rats' Rosemary Tee, Royal Brompton Hospital, an author of 'Reduction of airborne allergenic urinary proteins from laboratory rats'

Abstract Available for A case-control study of occupational risk factors for laryngeal cancer Wortley P, Vaughan TL, Davis S, Morgan MS, Thomas DB, A case-control study of occupational risk factors for laryngeal cancer, Brit J Industr Med, 1992;49:837-844,

No Abstract Available for Immediate and delayed allergy from epoxy resins based on diglycidyl ether of bisphenol A Kanerva L, Jolanki R, Tupasela O, Halmepuro L, Keskinen H, Estlander T, Sysilampi M, Immediate and delayed allergy from epoxy resins based on diglycidyl ether of bisphenol A, Scand J Work Environ Health, 1991;17:208-215,

No Abstract Available for Reactive airways dysfunction syndrome: a subset of occupational asthma Demeter SL, Cordasco EM, Reactive airways dysfunction syndrome: a subset of occupational asthma, J Disability, 1990;1:23-29,

Abstract Available for Accumulation of respiratory diseases among employees at a recently established refuse sorting plant. [Danish] Sigsgaard TI, Bach B, Taudorf E, Malmros P, Gravesen S, Accumulation of respiratory diseases among employees at a recently established refuse sorting plant. [Danish], Ugeskr Laeger, 1990;152:2485-2488,
Torben Sigsgaard, University of Aarhus, an author of 'Accumulation of respiratory diseases among employees at a recently established refuse sorting plant. [Danish]'

Abstract Available for Occupational asthma and rhinitis due to dust from oil-fired boilers Robertson AS, Burge PS, Occupational asthma and rhinitis due to dust from oil-fired boilers, Eur Respir J, 1990;3 suppl 10:173s-173s,
Sherwood Burge, Oasys, an author of 'Occupational asthma and rhinitis due to dust from oil-fired boilers' Alastair Robertson, Selly Oak Hospital, an author of 'Occupational asthma and rhinitis due to dust from oil-fired boilers'

Showing Page 8 of 9 Page: 3 4 5 6 7 8 9

Oasys and occupational asthma smoke logo