Sostrand P, Kongerud J, Eduard W, Nilsen T, Skogland M, Boe J, A test chamber for experimental hydrogen fluoride exposure in humans, Am Ind Hyg Assoc J, 1997;58:521-525,

Keywords: fluoride, alumina, ch

Known Authors

Johny Kongerud, Rikshospitalet, Oslo University, Norway Johny Kongerud

Jacob Boe, Bergen Jacob Boe

If you would like to become a known author and have your picture displayed along with your papers then please get in touch from the contact page. Known authors can choose to receive emails when their papers receive comments.

Abstract

An inhalation chamber was built to perform experimental studies with hydrogen fluoride (HF), other gases, and particulate matter. The present study sought to describe a new gas delivery system and the distribution and concentration of HF gas in the chamber. The aluminum chamber has a volume of 19.2 m3 and a variable ventilation rate of about 1 to 10 air changes per hour. The negative pressure difference between the chamber and outside air can be regulated from 0 to 300 Pa. HF was fed at concentrations of up to 4000 mg/m3 directly into the ventilation duct feeding the chamber through openings with diameters as small as 50 microns, oriented opposite to the airflow. Gas flow was varied from about 0.1 dm3/min at a pressure of 4 atm. The dilution factor of HF concentration from cylinder to chamber was on the order of 10(3) to 10(4). The standard deviation (SD) of the HF concentrations at a fixed measurement point during a 1-hour test was typically 0.05 mg/m3 at a time-weighted average (TWA) concentration of 2.66 mg/m3. The SD of the TWA HF concentrations at six locations in the chamber was typically 0.05 mg/m3 and 0.29 mg/m3 at 0.61 and 3.46 mg/m3, respectively. Human exposure could be predicted from calculations based on ventilation data, gas flow, and observed ratio between calculated and measured concentrations. When the target exposure concentration was 1.5 mg/m3, the measured mean exposure concentration was typically 1.54 mg/m3 (range: 1.4-1.7 mg/m3, SD 0.09 mg/m3, n = 8). The chamber is well-suited for inhalation studies in humans. Chamber atmosphere was controlled and has proved to be stable and homogeneous, even in tests with HF, a highly reactive gas in the class of superacids

Full Text

Full text of this reference not available

Please Log In or Register to add the full text to this reference

Comments

Please sign in or register to add your thoughts.


Oasys and occupational asthma smoke logo