Occupational Asthma Reference

Renström A, Björing G, Höglund AU, Evaluation of individually ventilated cage systems for laboratory rodents: occupational health aspects, Lab Animal, 2001;35:42-50,
(Plain text: Renstrom A, Bjoring G, Hoglund AU, Evaluation of individually ventilated cage systems for laboratory rodents: occupational health aspects, Lab Animal)

Keywords: laboratory animal, control, Sweden, air measurement, mouse, Mus m1, antigen,

Known Authors

If you would like to become a known author and have your picture displayed along with your papers then please get in touch from the contact page. Known authors can choose to receive emails when their papers receive comments.

Abstract

New ventilated caging systems for laboratory animals were compared with conventional caging regarding allergen distribution, ergonomic suitability, cage environment and animal welfare. This paper presents occupational health evaluations. Mice were placed in individually ventilated cage (IVC) systems, a ventilated cabinet, and in cages on open shelves (conventional husbandry). The IVC systems were studied at negative and positive airflow. Aeroallergens were sampled on filters (n = 204, including controls) in undisturbed rooms and during cage changing. Concentrations of mouse urinary allergen (Mus m 1) in filter eluates were measured using sandwich ELISA. An ergonomic evaluation was performed with measurement of traction forces. Staff exposure during cage changing was high in all systems, range 116-4430 ng Mus m 1/m3. In undisturbed animal rooms, allergen levels were orders of magnitude higher when using conventional caging compared with ventilated systems; P < 0.001. At positive pressure both IVCs leaked allergen (median Mus m 1 concentration was < 0.08 ng/m3 at negative, but 6.5 ng/m3 (IVC1) and 0.8 ng/m3 (IVC2S) at positive pressure). The IVC systems had ergonomic disadvantages compared with the conventional husbandry and the ventilated cabinet, for instance with cages in unsuitable working heights. Ventilated husbandry solutions reduce levels of airborne allergen substantially at negative pressure, but are ergonomically less suitable. To prevent allergen exposure during cage changing, we propose that this procedure should be performed under ventilated conditions. Producers and users must cooperate in optimizing animal caging systems for both animals and staff.

Full Text

Full text of this reference not available

Please Log In or Register to add the full text to this reference

Comments

Please sign in or register to add your thoughts.


Oasys and occupational asthma smoke logo