Occupational Asthma Reference

ReebWhitaker CK, Harrison DJ, Jones RB, Kacergis JB, Myers DD, Paigen B, Control strategies for aeroallergens in an animal facility., J Allergy Clin Immunol, 1999;103:139-146,

Keywords: laboratory animal, exposure, control

Known Authors

If you would like to become a known author and have your picture displayed along with your papers then please get in touch from the contact page. Known authors can choose to receive emails when their papers receive comments.

Abstract

BACKGROUND: Prevalence of the occupational disease laboratory animal allergy could be reduced if aeroallergen reduction strategies are identified.

OBJECTIVE: To reduce worker exposure to Mus m 1, an allergen from laboratory mice, the effect of filter cage tops, increased room ventilation, negatively pressurized ventilated cages, and ventilated cage-changing tables were evaluated.

METHODS: Aeroallergen was collected in the ambient air and in the breathing zone and quantified by using a competitive immunoassay.

RESULTS: When mice were housed in unventilated cages, ambient allergen was reduced from 5.1 ng/m3 with no cage top to 1.3 ng/m3 with a simple filter-sheet top and 0.8 ng/m3 with a fitted filter-bonnet top (P <. 05). Room ventilation was increased from 6 to 10, 15, and 20 air changes per hour and had little effect on aeroallergen levels and no impact on airborne particulate matter. When mice were housed in ventilated cages, ambient allergen was significantly reduced from 1. 1 ng/m3 at positive cage pressure to 0.3 ng/m3 at negative cage pressure (P <.05). Negative cage pressure combined with handling animals under a ventilated table reduced breathing zone allergen from 28 ng/m3 with neither control strategy in place to 9 ng/m3 (P <. 05). Use of a ventilated table controlled bacterial contamination, measured as colony forming units, found in negatively pressurized cages.

CONCLUSION: Three aeroallergen control strategies are use of filter cage tops, operation of negatively pressurized cages, and use of ventilated changing tables.