Occupational Asthma Reference

Fox J, Anderson H, Moen T, Gruetzmacher G, Hanrahan L, Fink J, Metal working fluid-associated hypersensitivity pneumonitis: an outbreak investigation and case-control study, Am J Ind Med, 1999;35:58-67,

Keywords: hf, IgG, USA, outbreak, metal working fluid, prevalence, oil

Known Authors

If you would like to become a known author and have your picture displayed along with your papers then please get in touch from the contact page. Known authors can choose to receive emails when their papers receive comments.

Abstract

Occupational exposure to bacterial or fungal antigens has been associated with hypersensivity pneumonitis (HP), an immunologically-mediated pulmonary disease. Between August 1995 and April 1996, 34 employees working in machining and assembly areas of an engine manufacturing plant were clinically diagnosed with HP. Of these, 20 employees met an epidemiologic case definition. In a case-control study, no exposure variables, including duration and intensity of metal working fluid (MWF) exposure, were statistically associated with an increased risk of disease. Neither cases nor controls demonstrated precipitin reactivity against unused samples of the seven MWF and two biocides used in the plant. HP cases had a significantly higher prevalence of positive precipitin reactions to used oil soluble and synthetic MWFs. Reactivity to used but not unused MWF suggests a biocontaminant, probably bacteria or fungi, is the causative antigen in the development of HP in this setting