Occupational Asthma Reference
Gadon ME, Melius JM, McDonald GJ, Orgel D,
New-onset asthma after exposure to the steam system additive 2-diethylaminoethanol. A descriptive study,
J Occup Med,
1994;36:623-626,
|
|
Keywords: oa, new, air-conditioning, office, nc, 2-diethylaminoethanol, peak flow
Known Authors
If you would like to become a known author and have your picture displayed along with your papers then please get in touch from the contact page. Known authors can choose to receive emails when their papers receive comments.
Abstract
Through a leak in the steam heating system, the anticorrosive agent 2-diethylaminoethanol was released into the air of a large office building. Irritative symptoms were experienced by most of the 2500 employees, and 14 workers developed asthma within 3 months of exposure. This study was undertaken to review clinical characteristics of these asthmatics. Environmental exposure monitoring data and medical records were reviewed. Seven of 14 cases were defined as "confirmed" and 7 of 14 as "suspect," using the National Institute for Occupational Safety and Health surveillance case definition of occupational asthma. Spirometry was positive in 4 of 14 of the cases and peak flow testing in 10 of 14. Three cases were diagnosed on the basis of work-related symptoms and physical examination alone. The study suggests that acute exposure to the irritating steam additive 2-diethylaminoethanol was a contributing factor in the development of clinical asthma in this population