Occupational Asthma Reference

Cartier A, Vandenplas O, Grammer LC, Shaughnessy MA, Malo JL, Respiratory and systemic reaction following exposure to heated electrostatic polyester paint, Eur Respir J, 1994;7:608-611,

Keywords: oa, polyester, polyethylene, fever, hf, br, case report

Known Authors

André Cartier, Hôpital de Sacré Coeur, Montreal, Quebec, Canada André Cartier

Olivier Vandenplas, Universite Mont-Goginne, Yvoir Olivier Vandenplas

Jean-Luc Malo, Hôpital de Sacré Coeur, Montreal, Quebec, Canada Jean-Luc Malo

If you would like to become a known author and have your picture displayed along with your papers then please get in touch from the contact page. Known authors can choose to receive emails when their papers receive comments.

Abstract

A 39 year old nonatopic man developed episodes of cough, dyspnoea, sweating and shivers within 2-3 weeks of starting a new job in a factory where metallic boards were treated with an electrostatic powder paint, made of an epoxy resin and a carboxylated polyester containing polyethylene terephthalate and polybutylene terephthalate. The subject sprayed the metallic boards which were then heated in 200 degrees C ovens. The subject was first seen in an emergency room after being at work for 4 h. The physical examination revealed bilateral wheezing with fever (39 degrees C), hypoxaemia (arterial oxygen tension (PaO2) 58 torr (7.7 kPa), leucocytosis (white blood count cells.mm-3 17,000 (17 x 10(9) cells.l-1) and severe airway obstruction (forced expiratory volume in one second (FEV1)/forced vital capacity, (FVC) 1.3/2.4 l, improving to 2.2/3.8 l after bronchodilator; predicted values = 3.4/4.1 l). The subjects condition improved after being treated with oral steroids. His spirometry was normal two weeks later, although he showed mild bronchial hyperresponsiveness to methacholine with the (provocative concentration producing a 20% fall in FEV1 (PC20) being 1.7 mg.ml-1). The subject underwent specific inhalation challenges at the workplace 4 months later. After being exposed at work for 4 h, he developed a significant fall in FEV1 (-40%), fever, leucocytosis, and a fall in diffusing capacity. Lung function tests were back to normal two weeks later. Exposing the subject to heated granulated polyester for one hour in a hospital laboratory produced a fall in FEV1 of 41%, fever, leucocytosis and a fall in diffusing capacity.(ABSTRACT TRUNCATED AT 250 WORDS)

Full Text

Full text of this reference not available

Please Log In or Register to add the full text to this reference