Occupational Asthma Reference
Rando RJ, Hammad YY, Chang SN,
A diffusive sampler for personal monitoring of toluene diisocyanate (TDI) exposure; Part II: Laboratory and field evaluation of the dosimeter,
Am Ind Hyg Assoc J,
1989;50:8-14,
|
|
Keywords: oa, TDI, isocyanate, am
Known Authors
If you would like to become a known author and have your picture displayed along with your papers then please get in touch from the contact page. Known authors can choose to receive emails when their papers receive comments.
Abstract
A passive monitor for TDI which utilizes microporous Teflon diffusion membranes and a 0.5% sulfuric acid (H2SO4) absorbing medium was evaluated. The collection rate of TDI is proportional to exposure dose from 10 to at least 300 ppb.hr, and response is equivalent for 2,4- and 2,6-TDI. Collection rate is independent of humidity and normal atmospheric pressure variations, while temperature causes a decrease of 1.0% per degree centigrade. Negative interference caused by ambient nitrogen dioxide (NO2) is eliminated by addition of sulfamic acid (HSO3 NH2) to the collecting medium. N-ethylmorpholine is a positive interferent. Field testing of the sampler against a reference impinger technique indicated a positive bias when TDI is aerosolized
Full Text
Full text of this reference not available
Please Log In or Register to add the full text to this reference
Comments
Please sign in or register to add your thoughts.