Occupational Asthma Reference
Sjostedt L, Willers S,
Predisposing factors in laboratory animal allergy: a study of atopy and environmental factors,
Am J Ind Med,
1989;16:199-208,
|
|
Keywords:
Known Authors
If you would like to become a known author and have your picture displayed along with your papers then please get in touch from the contact page. Known authors can choose to receive emails when their papers receive comments.
Abstract
A population of 101 laboratory technicians handling laboratory animals was studied with regard to predisposing factors for allergy. Twenty-seven had symptoms indicating laboratory animal allergy (LAA); of these, nine had asthma and were skin prick test positive for animal allergens. The LAA asthmatics had an increased frequency of a family history of allergy (relative risk, RR = 3.8); the predictive value was 0.27. There was also an increase of skin prick positivity against common nonanimal allergens (RR = 15); the predictive value was 0.60. All persons with marked positive skin prick tests (greater than or equal to +2) to environmental allergens had developed animal-test-positive LAA asthma. In 56% of the LAA asthma cases the serum IgE levels were elevated (greater than 100kU/L). In preemployment screening of susceptible individuals two important selection criteria emerged, viz., family history of allergy and positive skin prick reactions against environmental allergens.
Full Text
Full text of this reference not available
Please Log In or Register to add the full text to this reference
Comments
Please sign in or register to add your thoughts.