Occupational Asthma Reference

Tee RD, Graneek BJ, Burge PS, Newman Taylor AJ, Specific IgE responses in isocyanate-induced asthma, J Allergy Clin Immunol, 1989;101:709-715,

Keywords: oa, IgE, isocyanate, TDI, MDI, HDI, ch, abstract

Known Authors

Sherwood Burge, Oasys Sherwood Burge

Tony Newman Taylor, Royal Brompton Hospital, London Tony Newman Taylor

Rosemary Tee, Royal Brompton Hospital Rosemary Tee

If you would like to become a known author and have your picture displayed along with your papers then please get in touch from the contact page. Known authors can choose to receive emails when their papers receive comments.

Abstract

BACKGROUND
Isocyanates are the most frequent cause of occupational asthma in industrialized countries.

OBJECTIVE
We sought to investigate the utility of specific IgE measurement in the diagnosis of isocyanate-induced asthma.

METHODS
Fifty-eight of 101 patients referred for investigation were diagnosed as having isocyanate-induced occupational asthma by means of history, serial peak flow records, and bronchial provocation tests. Specific IgE antibodies to toluene diisocyanate:human serum albumin (HSA), diphenylmethane diisocyanate:HSA, and hexamethylene diisocyanate: HSA were measured in all patients by Phadebas RAST.

RESULTS
Twenty patients had a RAST ratio of 2 or greater to at least one isocyanate. Thirteen (28%) of the 46 patients with a positive provocation test response had a RAST ratio of 2 or greater, and nine (20%) had a RAST ratio of 3 or greater. Raising the RAST cut-off from 2 or greater to 3 or greater reduced its sensitivity but increased the specificity of the test to 100%. RAST measurement was most likely to be positive within 30 days of exposure. Serial measurements suggested that the half-life of the IgE antibodies was approximately 6 months. Evidence of cross-reactivity between isocyanate RAST responses was found in eight subjects.

CONCLUSION
Specific IgE to isocyanates is a more specific than sensitive index of occupational asthma. With a RAST score of 3 or greater, it is wholly specific and therefore diagnostic of isocyanate-induced asthma. The sensitivity of specific IgE measurement is highest when blood is taken less than 30 days from last exposure, which is consistent with the observed half-life.

Full Text

Full text of this reference not available

Please Log In or Register to add the full text to this reference

Comments

Please sign in or register to add your thoughts.


Oasys and occupational asthma smoke logo