Oxhoj H, Bake B, Wedel H, Wilhemsen L, Effects of electric arc welding on ventilatory lung function, Arch Environ Health, 1979;34:211-217,

Keywords: oa, welder, shipyard, cc, ep, ps, pft

Known Authors

If you would like to become a known author and have your picture displayed along with your papers then please get in touch from the contact page. Known authors can choose to receive emails when their papers receive comments.

Abstract

Respiratory symptoms, spirometry, forced expiratory flows, and the nitrogen closing volume test were studied in 119 welders and 90 controls, matched with respect to age, height, and smoking habits. Respiratory symptoms according to a questionnaire were more prevalent in the welders. No short-term changes of the measured variables during the day or week attributable to welding were found in twenty-one nonsmoking welders. Compared to the controls, closing volume and closing capacity (i. e., closing volume + residual volume) were significantly higher, and total lung capacity and the amplitude of the cardiogenic oscillations in the nitrogen curve were significantly lower in the welders who were nonsmokers or exsmokers, whereas there were no differences among smokers. These findings in welders may be attributable to deposition of welding fume particles in peripheral small airways or alveoli.