Table below is from two case reports of occupational asthma.

Agent Hydroxylamine (a replacement for Glutaraldehyde)
Job Deinking recycled paper
Specific IgE
Skin prick test
Non-specific reactivity abnormal in 2/2. Improved in 2/2 after removal from exposure.
Serial Peak Flow positive in 2/2. Oasys scores 2.85 and 2.67
Induced sputum
FENO
Specific Challenge

late reaction to aerosolised hydroxylamine; lesser reaction when painted

Follow-up

Better after relocation away from exposure, improving NSBR